ABL 800 Series
Blood gases,

Параметр Значение Ед. измерения
Основные параметры
Acceptable anticoagulants/Sampling technique heparin, electrolyte-balanced heparin/autoaspiration, syringe, capillary tube, test tube
Analytes measured on device pH, pCO2, pO2, Hb, Na, K, Cl, iCa, lactate, glucose, bilirubin, fetal Hb, O2Hb, MetHb, RHb, COHb, O2SAT, creatinine
Analytical method(s) or technologies employed pH: pH-sensitive glass (ISE); pCO2, pO2, Na, Cl, iCa, K, ISE; Hct: calculated from measuring Hb, bilirubin; Hb: optical, multiwavelength analysis, intra-cuvette ultrasonic hemolysis, and more
Analyzer connections Radiance stat information management system that connects to LIS/HIS or directly to LIS/HIS
Average life expectancy of device 20 years, with full support
Barometric pressure measured
Built-in printer/Data port yes/RS-232, Ethernet, USB
Calibration can be interrupted to perform stat sample yes
Calibration frequency 1 point: 30 minutes BG/pH, 4 hours—manufacturer; 2 point: every 8 hours
Calibrations required 1 and 2 point (automatic)
Categorized for point-of-care?testing or laboratory point-of-care?testing and laboratory
Contents downloaded from data management system to analyzer
Cost per test/Reagent cost per test depends on sample volume and any extra included items/same
Device is part of a series of related models yes (ABL 800 series)
Device warranty/Loaner devices provided 2 years, parts, labor, and travel/yes
Dimensions (H x W x D)/Weight 22 ? 28 ? 21 inches/70 pounds
Disposable prepackaged system used for analysis
Distinguishing features (provided by company) IDMS-traceable creatinine; FLEXQ automated inlet part of automatic system; bilirubin and fetal Hb measured on whole blood with no extra sample volume, low maintenance and cost of operation; FDA approved for the measurement of pleural fluid pH
First year sold 2004
For what bar-code scanning is provided operator and patient IDs, reagent and QC lot numbers, expiration, software keys
Hardware and software for data management system internal system plus optional external system, Radiance
How analyzer connects to external system to upload patient and QC results direct serial, modem dial-in, real-time wireless
Information included in transmission from analyzer to external system device-unique identifier, operator and patient IDs, results, QC identifier, per ASTM/HL7 standards plus calibration and analyzer status information
Information listed on hard copy report patient information and demographics, patient therapy settings, measures and calculates results, system messages, reference and critical ranges
Instrument response for calibration failure
Instrument response for hardware failure/software failure HW/SW: system message with customized (traffic light) visual and audible signals, parameter status bar
Instrument response for QC failure
Interface standards supported ASTM, HL7, serial, POCT1-A, network TCP/IP
Internal QC program recommended depends on hospital management and inspection agency
Known interferences halothane, thiocyanic, and glycolic acids
Max. No. of analyte reagents that can reside in device at once 4
Maximum No. of patient samples per hour/Maximum No. measured results per hour 25/425
Method of analyst ID in system customizable onboard keyboard, barcode
No. of different disposable reagents required to maintain device 4
No. of different management reports system produces user-definable searches and reports
No. of disposable reagent system units in standard package
No. of samples analyzed per one disposable reagent, electrode system
Number of devices sold in U.S./outside U.S./List price —/—/depends on configuration
Open or closed system/External gas tanks required closed/yes (low-pressure, premixed)
Optimal throughput when analyzer calibrated, awaiting specimens 25 tests per hour
Parameters calculated on device Hct, BE, TCO2, HCO3-, plus 40 additional parameters
Point of care:
Producer Radiometer America Inc.
QC features/Capabilities of QC features L-J plots/comparable plot (via DMS), statistical calcs., automatic QC, monthly cumulative reports (onboard and available with external system)
Reagent unit storage requirements
Remote control of device from laboratory yes
Sample size differs with number of analytes selected yes, with fewer measured parameters, smaller micro-modes available from 35 µL
Sample size for complete panel of analyte results 95 µL for 17 measured parameters
Sampler has self-wiping probe yes
Service center performs diagnostics through modem yes
Shelf life of components reagent, electrode, membrane kit, cartridge: 2+ years
Shelf life of disposable units
Specimen types suitable for device whole blood, capillary, mixed venous, arterial, venous, expired air
System can use LOINC to transmit results to LIS yes
System connected (live installations) to which LISs, HISs Cerner, McKesson, Meditech, Sunquest, many others
Time from sample introduction to result availability ~1 minute (depends on tests ordered)
Time required for maintenance by lab personnel monthly: as needed; annually: dependent on version
Use a third-party interfacing tool, engine for LIS, HIS interfaces an interfacing tool or engine could be used if customer requires it

;