Stat Profile Prime ABG
Blood gases,

Параметр Значение Ед. измерения
Основные параметры
Acceptable anticoagulants/Sampling technique heparin/aspiration, capillary transfer and fill
Analytes measured on device pH, pC02, p02
Analytical method(s) or technologies employed
Analyzer connections data-management system, which connects to LIS/HIS
Average life expectancy of device 5–7 years
Barometric pressure measured
Built-in printer/Data port yes/RS-232, Ethernet
Calibration can be interrupted to perform stat sample yes
Calibration frequency 1 point (variable); 2 point (variable)
Calibrations required 1 and 2 point (automatic)
Categorized for point-of-care?testing or laboratory point-of-care testing and laboratory
Contents downloaded from data management system to analyzer patient names, passwords
Cost per test/Reagent cost per test depends on volume/—
Device is part of a series of related models yes (Stat Profile Prime CCS has the same menu plus Hct, Na, K, CI, iCa, glucose, lactate)
Device warranty/Loaner devices provided 1 year/yes
Dimensions (H x W x D)/Weight 15.4 ? 12.0 ? 14.4 inches/17.9 pounds
Disposable prepackaged system used for analysis reagent, electrode (multiuse cartridge, MicroSensor Card)
Distinguishing features (provided by company) Zero Maintenance MicroSensor Cartridge technology uses proven Nova measurement technology in a miniaturized sensor card format; unique Clot Block flow path is designed to eliminate downtime associated with the introduction of a clotted sample; individual cartridges for sensors, calibrators, and liquid QC optimizes the life of each element compared to a combined calibrator/sensor cartridge design
First year sold 2014
For what bar-code scanning is provided operator identifier, patient identifier, reagent information is automatically captured when installed
Hardware and software for data management system
How analyzer connects to external system to upload patient and QC results hospital network
Information included in transmission from analyzer to external system device unique identifier, operator ID, patient ID, results, QC identifier
Information listed on hard copy report patient ID with accession numbers, entered settings, measured and calculated results
Instrument response for calibration failure any test that does not calibrate will not report results
Instrument response for hardware failure/software failure self-diagnosis software informs and notifies operator of hardware and software failures
Instrument response for QC failure options range from flagging to not reporting test to lockout for QC failure or exceeding scheduled QC interval
Interface standards supported ASTM 1394, HL7
Internal QC program recommended minimum CLIA recommendations
Known interferences
Max. No. of analyte reagents that can reside in device at once 1
Maximum No. of patient samples per hour/Maximum No. measured results per hour 45/450
Method of analyst ID in system multilevel password with unique user ID number (customizable)
No. of different disposable reagents required to maintain device 1
No. of different management reports system produces >30
No. of disposable reagent system units in standard package 1
No. of samples analyzed per one disposable reagent, electrode system varies
Number of devices sold in U.S./outside U.S./List price
Open or closed system/External gas tanks required closed/no
Optimal throughput when analyzer calibrated, awaiting specimens 450 tests per hour
Parameters calculated on device 02SAT, BE, TCO2, HCO3
Point of care:
Producer Nova Biomedical
QC features/Capabilities of QC features L-J plots, comparable plot/statistical calculations, monthly cumulative reports, true liquid quality control
Reagent unit storage requirements none
Remote control of device from laboratory no
Sample size differs with number of analytes selected no
Sample size for complete panel of analyte results 50 µL
Sampler has self-wiping probe yes
Service center performs diagnostics through modem no
Shelf life of components reagents: 12 months; MicroSensor Card: 12 months
Shelf life of disposable units reagents: 12 months at room temperature
Specimen types suitable for device whole blood, capillary, mixed venous, arterial, venous
System can use LOINC to transmit results to LIS yes
System connected (live installations) to which LISs, HISs most commercially available LIS/HIS
Time from sample introduction to result availability 60 seconds
Time required for maintenance by lab personnel monthly: <5 minutes
Use a third-party interfacing tool, engine for LIS, HIS interfaces yes, most commercially available interfaces

;